• Users Online: 652
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 31  |  Issue : 3  |  Page : 266-272

Comparison of endoscopic ultrasound-guided tissue acquisition using 22 G versus 20 G procore needles in solid lesions: a pilot study


1 Department of Gastroenterology and Hepatology, Mansoura Specialized Medical Hospital, Mansoura University, Mansoura, Egypt
2 Department of Anesthesia and Intensive Care, Mansoura University, Mansoura, Egypt
3 Department of Pathology, Mansoura University, Mansoura, Egypt

Correspondence Address:
MD Ahmed Altonbary
Department of Gastroenterology and Hepatology, Mansoura Specialized Medical Hospital, Mansoura University, Mansoura 35516
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ejim.ejim_118_18

Rights and Permissions

Background and aim Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) allows tissue acquisition from solid lesions. The endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) needle was developed to improve diagnostic yield by acquisition of histological core. The impact of the needle type (FNA or FNB) on the diagnostic yield and the technical success needs to be further studied. Therefore, the aim of our study was to compare the diagnostic accuracy and technical success of the 22-G FNA needle with the 20-G procore FNB needle in solid lesions. Patients and methods The study was designed as a pilot study conducted on cases with solid mediastinal, pancreatic, and intra-abdominal lesions, and the patients involved were then randomized for tissue sampling using either the standard 22-G FNA needle or the new 20-G procore FNB needle. Results In this six-month study, 50 patients including 29 male individuals and 21 female individuals, with a mean age of 57.1±12.3 years (range: 15–80 years) were enrolled. No significant difference was detected between FNA 22 G and FNB 20 G as regards the diagnostic accuracy or the technical success rates. However, there was a significant difference in the number of passes needed to reach diagnosis. The success rate of first pass for FNA 22 G and FNB 20 G was 69 and 92.5%, respectively (P=0.014, 95%CI). Conclusion EUS-guided FNA and FNB have comparable diagnostic accuracy for solid lesions. The 20-G FNB needles are easy to handle in anatomically challenging locations and required fewer needle passes to reach diagnosis.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1247    
    Printed128    
    Emailed0    
    PDF Downloaded167    
    Comments [Add]    

Recommend this journal